All posts tagged “HVAC”

Better HVAC Design

Flow Path of Air Matters in Patient Rooms

Air is the primary carrier of heat, moisture, contaminants and airborne pathogens in healthcare facilities such as patient rooms, isolation rooms and operating rooms. Recommended flow rate of supply air or number of air changes per hour are developed by considering only the overall dilution of the contaminants in the exhaust air streams. However, the flow path of supply air and how it is distributed is important in understanding the distribution of heat and contaminants within the space.

The flow path of supply air determines thermal comfort, air quality and potential for transmission of airborne pathogens in the patient room. Airflow patterns within a patient room can depend on several factors, including the location and type of supply diffusers, supply airflow rates (air change rates) and associated diffuser throws, supply air temperature, size and locations of room return, bathroom exhaust flow rates, locations and strengths of various heat sources in a room, arrangement of furniture and other obstructions to airflow and relative location of a patient in the room.

Visualization of airflow patterns and real-life evaluation and testing all the parameters that affect the airflow distribution is time consuming and labor intensive, if not impossible. In such situations, computational fluid dynamics simulations become an attractive alternative to analyze and optimize the performance of HVAC system configuration with real-life scenarios. CFD has been widely employed in the design and optimization of various products and processes in a variety of industries ranging from aerospace, automotive to chemical and biomedical. CFD is based on scientific laws of physics related to transport of fluid, heat and mass within a space.

CFD simulations help in visualization of airflow patterns, temperature distribution, concentration of contaminants and flow path of airborne pathogens in a 3-D space. CFD analyses provide valuable insights, which help in improving the designs and in developing mitigation strategies in the case of problem resolution.

Virtual Patient Room
In a recent study, a virtual patient room was created with the help of CFD simulation to understand how the location of a return grill in a patient room can affect the airflow patterns, temperature distribution and the probable flow path of airborne pathogens. The 3-D CFD model of a patient room included a patient, a caretaker, seating area, door to the corridor, door to the bathroom and supply and return air locations (figure 1). This analysis was performed for two different HVAC configurations – one near the room door and the other over the patient’s head. The room contains heat-generating equipment including lighting, monitor, infusion pump, television, computer and two occupants – the patient and the caretaker.

                                                                                                                  Figure1a_1b

a) Case 1: room return is located near the door
b) Case 2: room return moved behind the supply diffuser
Figure 1: Schematic diagram of CFD models for the analysis of a patient room showing two different locations for the return grill.

The air is supplied through three single-slot linear diffusers. The two linear diffusers placed on the drop ceiling are directed toward the window to account for the solar heat gain from the window. The linear diffuser over the patient is designed to supply air at an angle directed toward the room. The room was assumed to operate under slightly negative pressure with the exhaust flow from the bathroom exhaust fan. The probable flow paths of airborne pathogens are analyzed by tracking the path of air streams emerging from the patient’s face.

Valuable Insights
These analyses provided valuable insights into the 3-D airflow patterns, temperature distribution and the resulting thermal comfort and, importantly, the probable flow path of airborne pathogens. Thermal comfort of occupants was analyzed by employing predicted mean vote index as described in ASHRAE 55 standard for thermal comfort. As mentioned before, two cases were analyzed for two different locations of the return air grill.

In the case 1 analysis, the linear supply diffuser is located right above the patient’s head and the return grill is located near the door. The exiting air jet from the supply diffuser forms a strong recirculating pattern over the patient and behind the bed. As a result, the air flows upward over the patient and gets entrained back into the supply air stream (figure 2a). As shown in figure 2b, this re-circulation creates a slightly higher air temperature near the patient’s head. Figure 2c shows the distribution of the PMV, the thermal comfort index, which varies from -3 (too cold) to +3 (too hot). PMV values of 0 indicate a thermally comfortable environment, which is indicated by the green color in figure 2c. As shown in this figure, at the 4-foot height from the floor, the occupant thermal comfort is at neutral level (PMV close to 0.0). However, the airborne pathogens releasing from the patient’s face can get pulled into the supply air stream and eventually spread into the entire room (figure 2d). It shows the supply diffuser becomes a vehicle to entrain and spread the pathogens into the room.

Figure 2a_b_c_d
Figure 2: Results for the case 1 analysis showing a) airflow patterns, b) temperature distribution, c) PMV distribution at 4-foot height and d) resulting flow path lines indicating probable trajectory of airborne particles released from the patient’s face. It shows even though patients and other occupants can be the thermally comfortable in the space, the airflow patterns in the room can spread the airborne pathogens released from patient’s face into the entire room.

Ideally, the supply air from the diffusers should pass over the patient and return back to the return grill in a single pass without mixing into the supply stream and without recirculating into the room. The modifications in the HVAC configuration of case 2 attempts to achieve this. For the case 2 analysis, the size of the return grill is increased and moved behind the supply diffuser over the patient’s head (figure 1b). Relocation of the return grill right behind the supply diffuser provides ready access for the return air to exit from the room without significant re-circulation.

Figure 3a_b_c_dFigure 3: Results for case 2: room return moved behind the supply diffuser showing a) airflow patterns, b) temperature distribution, c) PMV distribution at 4-foot height and d) resulting trajectory of airborne particles released from the patient’s face. It shows simple modifications in the HVAC configuration without changing air change rates can significantly improve the airflow patterns and resulting flow path of airborne pathogens without affecting the thermal comfort of occupants.

Such modification does not significantly affect the temperature distribution and resulting thermal comfort of occupants, but it significantly modifies the flow path of the return air and the airborne particles (figure 3). In this case, the supply air still moves over the patient but does not get pulled back into the supply air stream. The return air carrying airborne pathogens can readily exit the room without re-circulation. It clearly shows such simple modification in the HVAC configuration can potentially provide a single flow pass over the patient and can provide a cleaner environment, reduce the probability of entrainment of the airborne particles back into the supply air stream and can avoid the spreading of airborne pathogens in the room.

A virtual patient room was created with the help of CFD models to evaluate the impact of return grill location on the flow path of airborne pathogens. These analyses provided valuable insights into airflow patterns, temperature distribution, thermal comfort of occupants and, importantly, on the probable path of airborne particles (pathogens) in a patient room. The traditional HVAC configuration of placing the return grill near the room door can potentially pull the airborne pathogens released from the patient’s face back into the supply air stream and can eventually spread those into the entire room. However, a simple modification of placing the room return right behind the linear supply diffuser over the patient’s head can potentially create a cleaner environment by providing an easy pathway to airborne pathogens into the return grill, which can avoid re-circulation of contaminated air back into the room.

It should be noted, a combination of locations and type of supply diffusers, locations of the room return and supply airflow rates can affect the airflow patterns, which are quite complex and specific to a particular design configuration. Therefore, it is difficult reach to any general conclusions about the optimized design configuration and placement of supply diffusers and return grills in a patient room. However, this study demonstrates CFD analysis can be an effective tool in gaining insight and optimizing the design of air distribution systems in healthcare faculties. Such efforts can help in designing patient rooms with better occupant thermal comfort along with the best possible hygienic conditions.

Editor’s Note: This article was based on “Role of HVAC System Configuration on Probable Flow Path of Airborne Pathogens in a Patient Room,” a paper presented during ASHRAE’s annual conference held in Denver, Colorado. An abbreviated version of this article appeared in the July/August issue of MCD magazine.

ASHRAE Guideline On Specifying Building Automation Systems Open For Review

ATLANTA, Ga. — Guidance on performance monitoring is featured in a newly published guideline from ASHRAE. Read More …

Maine General Health’s New Regional Hospital to Open in November

AUGUSTA, Maine — The Alfond Center for Health, MaineGeneral’s new regional hospital, is set to open for patients next month. The project aims to better address the healthcare needs of the greater Kennebec Valley region. The $332-million project will replace the current Augusta and Seton facilities, to reduce cost and improve coordination of care. Read More …

Sundt Construction Completes Inpatient Rehabilitation Hospital

Sundt Construction, Inc. has completed a single-level, 54,000-square-foot inpatient rehabilitation hospital in Scottsdale, Ariz., supporting 50 private patient rooms and serving a variety of acute needs. Read More …

Looking Ahead: HVAC, Power Contingency Planning Offers Flexibility and Peace of Mind

Most hospitals and medical centers have contingency plans in place to help manage the consequences of natural disasters and building system failures that could impact normal operations and affect the healthcare organization’s ability to provide its normal high standard of patient care. A heating, ventilation and air conditioning or power system failure could have potentially devastating effects on the physical environment of care and — in the most severe cases — create life and death situations. Read More …

ASHRAE/IES Publish First Standard Focused on Commissioning Process

ATLANTA, Ga. — A newly published standard focused on the commissioning process will help ensure a fully functional, fine-tuned facility. Read More …

Breath of Fresh Air: Combining Air Purification Methods Enhances IAQ

Indoor air quality is an area of growing concern for healthcare facilities managers. Although ultraviolet germicidal irradiation light and gas-phase air purification are proven technologies, the combination of these technologies with photo catalytic oxidation offers a new and powerful tool for healthcare facility indoor air quality.  Read More …

Emcor Group Subsidiary to Install Fire Protection, Mechanical Systems for Ohio Medical Facilities

NORWALK, Conn. — EMCOR Group, Inc. recently announced that its subsidiary, S.A. Comunale, has been awarded a contract at Northeast Ohio Medical University Health and Wellness Center in Rootstown, Ohio. Read More …

Medical Center Earns PG&E Incentive Award for Energy Savings

SAN FRANCISCO, Calif. – An Arup-designed chilled-water system at UC San Francisco has earned a $757,000 energy efficiency award from PG&E, as well as a 2013 Higher Education Energy Efficiency and Sustainability Best Practice Award in the  HVAC Retrofit category.

The $7.7-million project for the UCSF Medical Center, which Arup designed and completed in January 2013, shifted the cooling production from old, inefficient absorption chillers, to new high-efficiency electric chillers, and upgraded the chilled-water distribution system to both hospitals on the campus. As a result, the project was confirmed by PG&E to save more than 65M kBtu of energy per year, with a projected annual savings of $1.3M in utility costs, more than $100,000 in maintenance costs and a simple payback of less than six years.

The resulting efficiency PG&E award represents the largest energy efficiency rebate for a single project at the university.

“It is uncommon in today’s business climate that an institution has the vision and patience to execute a project in a manner that defines best practice,” said Michael Sweeney, building retrofit practice leader at Arup. “What was traditionally viewed as an impending but necessary project has turned into an economic opportunity that allowed the medical center to take funds traditionally spent on utilities and divert them toward a renewal of vital infrastructure. It’s commendable.”

Arup, a multidisciplinary engineering and consulting firm, was originally hired to help devise a master plan for the chilled-water systems and to identify measurable and actionable improvements. Arup was retained as the prime consultant, leading a team of specialists to implement this Phase I portion of the master plan.

Arup and the hospital recognized early in the planning stage that technological improvements in modern equipment would allow the team to replace just one of the unreliable and inefficient 385-ton steam-driven absorption chillers with a much larger 600-ton electric centrifugal chiller. Then, by interconnecting the chilled-water systems of each hospital, the new chiller could efficiently deliver 95 percent of the annual cooling needs for both.  As a result, the reliability and efficiency benefits of the project were doubled to two hospitals.

Arup services included the conversion of the multiple, dysfunctional primary-only pumping systems to a common, modernized variable-speed primary/secondary pumping system; detailed infection-control planning for the replacement of major three-way chilled-water control valves with two-way valves in and around patient care areas; connection of the chilled-water system from one hospital into the upgraded chilled-water loop of the other for base load cooling and the implementation of new control systems that will automate the plant’s operation and calculate energy savings in real  time.

To ensure that the medical center remained operational during these extensive renovations, Arup devised a solution using stents (similar to the concept of heart surgery) that allowed specialty contractors and pipe fitters to work on parts of the chilled-water lines while water flowed through the bypass lines.

Within an operating hospital under California’s stringent Office of Statewide Health Planning and Development  jurisdiction, Arup helped reduce operations and maintenance costs, utility costs and green-house gas emissions, while greatly improving service reliability, system performance and cooling capacity for future growth.

Projects recognized in the HVAC Design/Retrofit category of the Higher Education Energy Efficiency and Sustainability Best Practice awards program should demonstrate leadership in HVAC equipment selection, distribution system design and controls specifications. The goals of the program, made possible by the Higher Education Energy Efficiency Partnership, are:

  • To highlight the achievements that California campuses have made through innovative and effective energy-efficiency projects and sustainable operations.
  • To showcase specific projects as models to be used by other campuses to achieve energy efficiency and sustainability goals.
  • To provide campus staff with a compendium of best practice projects that can be transferable to their campuses.

Project team members included:

  • Prime Consultant:                                Arup
  • Construction Manager:                       Jtec HCM
  • Prime Contractor:                                City Building
  • Mechanical Contractor:                      Southland Industries
  • Mechanical Engineer:                         Arup
  • Electrical Engineer:                             Cammisa and Wipf
  • Structural Engineer:                            Estructure
  • Architect:                                            The Design Partnership
  • Hydraulic Modeler:                              R&A Engineering Solutions
  • Acoustical Consultant:                        Arup
Scroll down or click here for more posts