Japanese Researchers Developing Desktop Air Curtain System for Hospitals

In efforts to prevent the spread of COVID-19, miniaturizing air curtains for hospital wards, labs and other healthcare settings is gaining traction as a viable solution to inadequate face masks or when social distancing is not a realistic option.

In AIP Advances, published by AIP Publishing, researchers in Japan developed a desktop air curtain system that blocks all incoming aerosol particles.

One challenge in developing smaller air curtains is fully blocking emitted aerosol particles over time because it is difficult to maintain the air wall over a long distance. As a result, the devices gradually lose air-discharge intensity, creating a turbulent flow that allows infected aerosol particles to escape into the surrounding environment.

The DACS contains a discharge and suction port to help address this problem. A generator at the top of the DACS produces the airflow, which is guided to the suction port at the bottom of the device. This prevents airflow dispersion, thus leading to the collection of all the aerosol particles at the suction port. A high-efficiency particulate air filter can be installed inside the suction port for air purification.

The researchers are developing an accompanying virus inactivation system equipped with ultraviolet light that connects to the suction port. After the air is sanitized with the UV light, it is recirculated to maintain airflow of the air curtain and air pressure in the room.

The researchers tested their device by using an air compressor connected to a mannequin to simulate breathing. Dioctyl sebacate was added to the airflow to create aerosol particles. Particle image velocimetry and high-speed cameras were used to determine the DACS’s blocking effect.

The aerosol particles approaching the DACS abruptly bent toward the suction port, signifying that air curtain flow fully blocked all incoming aerosol particles.

When the researchers placed the mannequin’s arm through the DACS to imitate a blood-collection scenario, they found the airflow above the arm was disrupted. However, the aerosol blocking performance remained unaffected.

The DACS was tested on patients during blood collection at Nagoya University Hospital. The researchers are looking at lowering the suction port, so the arm can be placed below the heart for proper blood collection.

The article “Blocking effect of desktop air curtain on aerosols in exhaled breath” is authored by Kotaro Takamure, Yasuaki Sakamoto, Tetsuya Yagi, Yasumasa Iwatani, Hiroshi Amano, and Tomomi Uchiyama.

Tags: ,

Posted May 21, 2022

More Articles: